3 GENERAL REQUIREMENTS P
Safety class of the apparatus : Class II P
4 GENERAL CONDITIONS OF TESTS P
4.1.4 Ventilation instructions require the use of the test box Yes P
5 MARKING P
Comprehensible and easily discernible P
Permanent durability against water and petroleum spirit P
5.1 Identification, maker, model : Identification: FUZE
Model: AVS21 P
Class II symbol if applicable N/A
Rated supply voltage and symbol : Mains: 100V~ P
Frequency if safety dependant 50/60Hz P
Rated current or power consumption : 24.9W P
5.2 Earth terminal N/A
Hazardous live terminals No hazardous live terminals N/A
Supply output terminals (other than mains) No socket outlet for providing power to other apparatus. N/A
5.3 Use of triangle with exclamation mark The mark is shown on the circuit diagram near to every safety critical component P
5.4 Instructions for use See below P
5.4.1 Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc. Stated in user’s manual. P
Hazardous live terminals, instructions for wiring No hazardous live terminals N/A
Instructions for replacing lithium battery No lithium battery N/A
Instructions for modem if fitted No such devices N/A
Class I earth connection warning P
Instructions for multimedia system connection N/A
Special stability warning for fixed installation N/A
Warning: battery exposure to heat N/A
Warning: protective film on CRT face N/A
5.4.2 Disconnect device: plug/coupler or all-pole mains switch location, accessibility and markings Stated in user’s manual P
Instructions for permanently connected equipment N/A
6 HAZARDOUS RADIATION N/A
6.1
EN 60065 European Council Directive 96/29/Euratom of 13 May 1996 10cm from outer surface of apparatus <1µSv/h (0,1mR/h) No ionising radiation N/A
6.2 Laser radiation, emission limits to IEC 60825-1 : No laser radiation N/A
Emission limits under fault conditions : N/A
7 HEATING UNDER NORMAL OPERATING CONDITIONS P
7.1 Temperature rises not exceeding specified values, no operation of fuse links (see appended table) P
7.1.1 Temperature rise of accessible parts (see appended table) P
7.1.2 Temperature rise of parts providing electrical insulation (see appended table) P
7.1.3 Temperature rise of parts acting as a support or as a mechanical barrier (see appended table) P
7.1.4 Temperature rise of windings (see appended table) P
7.1.5 Parts not subject to a limit under 7.1.1 to 7.1.4 (see appended table) P
7.2 Softening temperature of insulating material supporting parts conductively connected to the mains carrying a current > 0,2 A at least 150 oC (see appended table) P
8 CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION AGAINST ELECTRIC SHOCK P
8.1 Conductive parts covered by lacquer, paper, untreated textile oxide films and beads etc. considered to be bare Compliance checked by inspection P
8.2 No shock hazard when changing voltage setting device, fuse-links or handling drawers etc. No such parts can be operated by hand. N/A
8.3 Insulation of hazardous live parts not provided by hygroscopic material hygroscopic material checked by inspection approved P
8.4 No risk of electric shock following the removal of a cover which can be removed by hand There is no risk of an electric shock from ACCESSIBLE parts P
8.5 Class I equipment N/A
Basic insulation between hazardous live parts and earthed accessible parts N/A
Resistors bridging basic insulation complying with 14.1 a) No such resistor N/A
8.6 Class II equipment and Class II constructions within Class I equipment Class II equipment N/A
Reinforced or double insulation between hazardous live parts and accessible parts Double or reinforced insulation complies with requirements specified in clause 10 and 13 P
Components bridging reinforced or double insulation complying with 14.1 a) or 14.3 Transformers T1 comply with 14.3 P
Basic and supplementary insulation each being bridged by a capacitor complying with 14.1 a) No such capacitors. N/A
Reinforced or double insulation being bridged with 2 capacitors in series complying with 14.2.1 a) Ditto N/A
Reinforced or double insulation being bridged with a single capacitor complying with 14.2.1 b) Ditto. N/A
Basic insulation bridged by components complying with 14.3.4.3 No such components. N/A
8.8 Basic or supplementary insulation > 0,4 mm (mm) : Compliance P
Reinforced insulation > 0,4 mm (mm) : Bobbin of transformer T1 Min. 0.8mm P
Thin sheet insulation (excluding non-separable thin sheet insulation. See 8.22) There are at least 2 layers of insulation sheet warped around primary winding of transformer T1 P
Basic or supplementary insulation, at least two layers, each meeting 10.3 N/A
Basic or supplementary insulation, three layers any two of which meet 10.3 N/A
Reinforced insulation, two layers each of which meet 10.3 N/A
Reinforced insulation, three layers any two which meet 10.3 (see appended table) P
8.9 Adequate insulation between internal hazardous live conductors and accessible parts Internal hazardous live conductors are separated by double or reinforced insulation from accessible parts. P
Adequate insulation between internal hazardous live parts and conductors connected to accessible parts Accessible parts are separated by double or reinforced insulation from these conductors. P
8.10 Double insulation between conductors connected to the mains and accessible parts.
Double insulation between internal hazardous live parts and conductors connected to accessible parts. P
8.11
Detaching of wires P
No undue reduction of creepages or clearance distances if wires become detached P
Vibration test carried out : N/A
8.13 Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s) P
8.14 Adequate fastening of covers (pull test 50 N for 10 s) P
8.15 No risk of damage to the insulation of internal wiring due to hot parts or sharp edges No risk of damage to the insulation of internal wiring due to hot parts or sharp edges of the transformer. P
8.16 Only special supply equipment can be used N/A
8.17 Insulated winding wire without additional interleaved insulation No such winding wire. N/A
8.18 Endurance test as required by 8.17 N/A
8.19 Disconnection from the mains P
8.19.1 Disconnect device Appliance coupler provided as disconnect device P
All-pole switch or circuit breaker with >3mm contact separation N/A
8.19.2 Mains switch ON indication N/A
8.20 Switch not fitted in the mains cord Single pole mains switch fitted in rear enclosure P
8.21 Bridging components comply with clause 14 N/A
8.22 Non-separable thin sheet material N/A
9 ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS P
9.1 Testing on the outside P
9.1.1 For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation N/A
9.1.1.1 a) Open circuit voltages N/A
b) Touch current measured from terminal devices using the network in annex D : Live to terminals:
U1 = 186.0 mV (pk)
U2 = 28.0 mV (pk)
(limit: U1=35V(peak)
U2=350mV(peak)) P
c) Discharge not exceeding 45 μC < 45 μC P
d) Energy of discharge not exceeding 350 mJ N/A
9.1.1.2 Test with test finger and test probe No access with test finger to any parts bearing hazardous voltage P
9.1.2 No hazardous live shafts of knobs, handles or levers No hazardous live shafts P
9.1.3 Ventilation holes and other holes tested by means of 4 mm x 100 mm test pin No ventilation holes in the top of the enclosure N/A
9.1.4 Terminal devices tested with 1 mm x 20 mm test pin (10 N); test probe D of IEC 61032 P
Terminal devices tested with 1 mm x 100 mm straight wire (1 N); test probe D of IEC 61032 P
9.1.5 Pre set controls tested with 2.5 mm x 100 mm test pin (10 N); test probe C of IEC 61032 No pre-set controls N/A
9.1.6 No shock hazard due to stored charge on withdrawal of the mains plug; voltage (V) after 2 s : N/A
If C is not greater than 0,1 μF no test needed P
9.1.7 a) Enclosure sufficiently resistant to external force P
Test probe 11 of IEC 61032 for 10 s (50 N) P
b) Test hook of fig. 4 for 10 s (20 N) P
c) 30 mm diameter test tool for 5 s (100 or 250 N) : N/A
9.2 No hazard after removing a cover by hand N/A
10 INSULATION REQUIREMENTS P
10.1 Insulation resistance (MΩ) at least 2 MΩ min. after surge test for basic and 4 MΩ min. for reinforced insulation : No antenna terminals N/A
10.2 Humidity treatment 48 h or 120 h : 93%RH, 30C for 48h P
10.3 Insulation resistance and dielectric strength between mains terminals (see appended table) P
Insulation Resistance and dielectric strength across BASIC or SUPPLEMENTARY insulation (Class 1) N/A
Insulation resistance and dielectric strength across REINFORCED insulation (Class II) P
11 FAULT CONDITIONS P
11.1 No shock hazard under fault condition P
11.2 Heating under fault condition P
No hazard from softening solder No softening solder P
Flames extinguish within 10 seconds No flames in fault condition tests P
Soldered terminations not used as protective mechanism Inspected P
11.2.1 Measurement of temperature rises (see appended table) P
11.2.2 Temperature rise of accessible parts (see appended table) P
11.2.3 Temperature rise of parts, other than windings, providing electrical insulation (see appended table) P
Temperature rise of printed circuit boards (PCB) exceeding the limits of table 3 by max. 100 K for max. 5 min No such parts N/A
a) Temperature rise of printed circuit boards (PCB) to 20.1.3, exceeding the limits of table 3 by not more than 100 K for an area not greater than 2 cm² N/A
b) Temperature rise of printed circuit boards (PCB) to 20.1.3 up to 300 K for an area not greater than 2 cm² for a maximum of 5 min N/A
Meets all the special conditions if conductors on printed circuit boards are interrupted N/A
Class I protective earthing maintained N/A
11.2.4 Temperature rise of parts acting as a support or mechanical barrier N/A
11.2.5 Temperature rise of windings (see appended table) P
11.2.6 Temperature rise of parts not subject to the limits of 11.2.1 to 11.2.5 (see appended table) P
12 MECHANICAL STRENGTH P
12.1.1 Bump test where mass >7 kg N/A
12.1.2 Vibration test No hazards P
12.1.3 Impact hammer test No hazards P
Steel ball test 2J P
12.1.4 Drop test for portable apparatus where mass < 7 kg No hazards P
12.1.5 Thermoplastic enclosures strain relief test Enclosure in wood use N/A
12.2 Fixing of knobs, push buttons, keys and levers P
12.3 Remote controls with hazardous live parts No such remote controls N/A
12.4 Drawers (pull test 50 N, 10 s) N/A
12.5 Antenna coaxial sockets providing isolation N/A
12.6 Telescoping or rod antennas construction No such antenna N/A
12.6.1 Telescoping or rod antennas securement N/A
13
CLEARANCE AND CREEPAGE DISTANCES P
13.1 Clearances in accordance with 13.3 (see clause 13.3) P
Creepage distances in accordance with 13.4 (see clause 13.4) P
13.2 Determination of operating voltage Considered. P
13.3 Clearances See below. P
13.3.1 General P